Axis Medical Canada Inc.

West / Ouest: 1 888 855-6558​     Ontario: 1 800 267-5597     East / Est1 877 388-1515

Optopol Revo NX130

OT1-OP-REVONX130
OCT

the world`s first B-OCT and T-OCT for standard
posterior OCT

Optopol's engineering team, the designers of the first commercially available Spectral Domain OCT in the world, are proud to present the latest innovation, the world`s first B-OCT and T-OCT for standard
posterior OCT. Their supreme experience in Spectral Domain OCT allows them to provide the market with a state of the art instrument which comes with new advanced technologies and remarkable simplicity of operation.

New OCT standard - All functionality In One device.
Once again Revo NX goes beyond the limits of standard OCT. With its new scanning speed, the Revo NX 130 enables a full functionality scanning from the retina to the cornea. It brings benefits by combining the potential of several devices. With REVO you can measure, quantify, calculate and track changes from the cornea to the retina over time with just one OCT device.

i Tracking™
iTracking™ technology compensates involuntary eye movements and blinks. When OCT scan is used each anatomical region is acquired twice automatically. The system immediately creates an artifact-free MC examination using the Motion Correction TechnologyTM. The elimination of eye movement and blinking artifacts ensures the highest resolution of Angio OCT images without patient inconvenience. Clear OCTA data set allows easier interpretation of retinal vasculature conditions.

STRUCTURE & FUNCTION - Combined OCT and VF results analysis
Invaluable combination of information about the functional quality of vision with comprehensive data on Retinal Ganglion Cells, RNFL and Optic Nerve Head for both eyes on a single report page. The S&F report contains the following:

  • VF sensitivity results (24-2/30-2 or 10-2)
  • Total and Pattern Deviation probability graphs for VF results
  • Reliability and Global indices for VF results
  • Combined map of Structure & Function
  • Ganglion cell analysis (GCL+IPL or NFL+GCL+IPL)
  • ONH and NFL analysis including charts and comparison tables
  • NFL Asymmetry Plot 

The S&F report compares in a natural way the anatomical relationship between VF and RNFL/Ganglion maps.

BIOMETRY OCT is an optional software module to purchase
B-OCT™ innovative method of using the posterior OCT device to measure ocular structure along the eye axis.
OCT Biometry provides a complete set of Biometry parameters: Axial Length AL, Central Cornea Thickness CCT, Anterior Chamber Depth ACD, Lens Thickness LT.
All measurement calipers are shown on the "all boundaries" OCT image provided by REVO. Now, you can visually verify and correct what structure of the eye has been measured.

TOPOGRAPHY OCT is an optional software module to purchase
T-OCT™ is a pioneering way to provide detailed corneal Curvature maps by using posterior dedicated OCT. Anterior, Posterior surface and Corneal Thickness allow the Revo NX130 to provide the  True Net Curvature information. With Net power, the precise understanding of the patient’s corneal condition comes easily and is free of errors associated with modeling of the posterior surface of the cornea.  SOCT T-OCT module provides Axial maps, Tangential maps, Total Power map, Height maps, Epithelium, and Corneal thickness maps.
The corneal topography module clearly shows the changes in the cornea on the difference map view. Customize your
Topography module provides:

  • Full-featured Corneal mapping of Anterior, Posterior and Real
  • Precise Astigmatism Display Option (SimK: Anterior, Posterior, Real,  Meridian and Emi-Meridian ø 3, 5, 7 mm zones

KERATOCONUS SCREENING
Easily detect and classified keratoconus with the Keratoconus classifier. Classification based on KPI, SAI, DSI, OSI, and CSI. In the early stages of keratoconus, the results can be complemented by Epithelium and Pachymatery maps.

 

Documents

Brochure Brochure

Information request

Required *

Axis Medical

We are leaders in the industry providing you with the latest medical technology that helps grow your revenue and solidifies the relationship between you and your patients. We have four offices across Canada with local after-sales service and support for you. As well, we have an experienced, dedicated sales staff available to consult with you, ensuring all of your needs are met. We have developed relationships with suppliers from around the world to bring you reliable, high-quality ophthalmic technology, since 1980.

Offices

9260 Boul. Des Sciences
Anjou, Québec
H1J 3A9
1 877 388-1515

111 Adam Street, Unit B
Belleville, Ontario
K8N 5K3
1 800 267-5597

#1 - 1520 Cliveden Avenue
Delta (Vancouver), BC
V3M 6J8
1 888 855-6558

Advanced Optical Solutions (AOS)
67 Avenue Mowat, Suite 030
Toronto, ON
M6K 3E3
*By appointment only*

Events

OAO (Toronto)

POSTPONED / REPORTÉ

Friday April 3rd, from 1:30 to 4:30 p.m

MAO - Manitoba Association of Optometrists

POSTPONED / REPORTÉ

Friday April 17th, from 17:00 to 21:00

Devices advertised may not have been licensed in accordance with Canadian law.