Axis Medical Canada Inc.

West / Ouest: 1 888 855-6558​     Ontario: 1 800 267-5597     East / Est1 877 388-1515

Optopol Revo 60K

OT1-OP-REVO(60K)
OCT

AS SIMPLE AS PRESSING THE START BUTTON

OCT made simple as never before. All you have to do is to position the patient and press the START button to acquire examinations of both eyes. The device will make the examination independently. Small system footprint, various operator and patient positions allow installing SOCT Copernicus REVO even in the smallest examination rooms. Variety of review and analysis tools gives the operator a choice of using it as a screening or as an advanced diagnostic device. The noise reduction technology provides the finest details proven to be important for early disease detection.

Physical Distancing

RETINA
Single 3D Retina examination is enough to perform both Retina and Glaucoma analysis based on retinal scans. The software automatically recognizes 8 retinal layers. Thus allowing a more precise diagnosis and mapping any changes in the patient’s retina condition.

GLAUCOMA
Comprehensive glaucoma analytical tools for quantification of the Nerve Fiber Layer, Ganglion layer and Optic Head with DDLS allow for the precise diagnosis and monitoring of glaucoma over time.
With the golden standard 14 optic nerve parameters and a new Rim to Disc and Rim Absence, the description of ONH condition is quick and precise.
Advanced view which provides combined information from Retina and Disc scan to integrate details of the Ganglion cells, RNFL, ONH in a wide field perspective for comprehensive analysis.

Advance Retina & ONH             ONH Single
 

Asymmetry Analysis of Ganglion layers between hemispheres and between eyes allows easier identification and detection of glaucoma in the early stages and in non-typical patients.

Ganglion Both                            Ganglion Progression
 

Implemented the DDLS  - Disc Damage Likelihood Scale which uses 3 separate classifications for small, average and large discs. It supports the practitioners in a quick and precise evaluation of the patient’s
glaucomatous disc damages.

ONH Both                                   ONH Progression
 

COMPLETE YOUR GLAUCOMA REPORT
To eliminate the common problem with the understanding of the patient’s IOP pachymetry module provides IOP Correction value.  With the implemented Adjusted IOP formula, you can quickly and precisely understand the measured IOP value.  
As the Pachymetry and Anterior Chamber Angle Verification require no additional attachments, the predefined Glaucoma protocol, which consists of Retina, Disc, and Anterior scans, can be done automatically to reduce patient chair time.

Closing angle                             Anterior single view
 
* Images courtesy of Prof. Edward Wylęgała MD, PhD

ANTERIOR
For standard examinations, no additional lens is required.  Additional adapter provided with the device allows acquisition of wider scans of the anterior segment.

Cornea single                            Cornea both
 
Cornea Comparison                  Cornea Progression
  

Specifications

  • Technology: Spectral Domain OCT
  • Scanning speed: 60 000 measurements per second
  • Axial resolution: 5 μm in tissue
  • Transverse Resolution: 12 μm, typical 18 μm
  • Overall scan depth: 2.4 mm
  • Scan range: Posterior 5–12 mm, Anterior 3–16 mm
  • Scan program: 3D, Radial, B-scan, Raster, Cross

Documents

Brochure Brochure
Cleaning instructions Cleaning instructions

Information request

Required *

Axis Medical

We are leaders in the industry providing you with the latest medical technology that helps grow your revenue and solidifies the relationship between you and your patients. We have four offices across Canada with local after-sales service and support for you. As well, we have an experienced, dedicated sales staff available to consult with you, ensuring all of your needs are met. We have developed relationships with suppliers from around the world to bring you reliable, high-quality ophthalmic technology, since 1980.

Offices

9820 Boulevard Du Golf
Anjou, Québec
H1J 2Y7
1 877 388-1515

111 Adam Street, Unit B
Belleville, Ontario
K8N 5K3
1 800 267-5597

#8 - 7541 Conway Avenue
Burnaby, BC
V5E 2P7
1 888 855-6558

Devices advertised may not have been licensed in accordance with Canadian law.