Axis Medical Canada
West / Ouest: 1 888 855-6558 Ontario: 1 800 267-5597 East / Est: 1 877 388-1515
B-OCT® Innovative method of using the posterior OCT device to measure ocular structure along eye axis. OCT Biometry provides a complete set of Biometry parameters: Axial Length (AL), Central Cornea Thickness (CCT), Anterior Chamber Depth (ACD), Lens Thickness (LT), White to White (WTW), Pupil (P).
Overview
B-OCT® enables measurement of ocular axial dimensions using a conventional OCT system. During the examination, the scanning light beam passes through ocular structures located along the visual axis and the following are identified: the anterior and posterior boundary of the cornea, the anterior and posterior boundary of the lens, as well as the posterior boundary of the retina.
*Optional software module sold separately
The Myopia Forecast module opens progression of the ocular structure parameters according to trends over population mode. Usage reference based on research from multiple universities along with environmental factors allow the monitoring of changes from childhood to adolescence.
The REVO offers an exclusive selection of reference data based on different studies over different time frames and demographics. Reference data can be selected from the NICER San Diez or Tideman studies.
Verify your measurement visually
All measurement calipers are shown on all boundaries of OCT image provided by REVO. Now, you can visually verify, identify and if need be, make corrections as to which structure of the eye has been measured. With a simple cursor shift, it is possible to precisely set boundaries for every difficult patient.
From now on you can eliminate the common uncertainty as to how the optical biometer classifies the boundaries in non-typical patients.
3 mm scan allows precise evaluation of the Retina condition.
5 µm resolution gives the highest level of detail.




We are leaders in the industry providing you with the latest medical technology that helps grow your revenue and solidifies the relationship between you and your patients. We have four offices across Canada with local after-sales service and support for you. As well, we have an experienced, dedicated sales staff available to consult with you, ensuring all of your needs are met. We have developed relationships with suppliers from around the world to bring you reliable, high-quality ophthalmic technology, since 1980.
371 rue Deslauriers, suite 343
Saint-Laurent, QC
H4N 1W2
1 877-388-1515
111 Adam Street, Unit B
Belleville, Ontario
K8N 5K3
1 800 267-5597
#8 - 7541 Conway Avenue
Burnaby, BC
V5E 2P7
1 888 855-6558
Devices advertised may not have been licensed in accordance with Canadian law.